                <dim:dim>
                    <dim:field mdschema="dc" element="title" lang="en">Dynamic Balance and Alignment of Rotary Machines with Vibration Parameter Control</dim:field>
                    <dim:field mdschema="dc" element="date" qualifier="issued">2023</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="uri">http://ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai/record/3/10228</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="uri">https://link.springer.com/chapter/10.1007/978-3-031-19499-3_9#citeas</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:47711" confidence="-1">B. Novaković</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:47712" confidence="-1">M. Ristić</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:47713" confidence="-1">LJ. Radovanović</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:47714" confidence="-1">L. Đorđević</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="orcid::0000-0001-7412-7870" confidence="-1">J. Perišić</dim:field>
                    <dim:field mdschema="dc" element="description" qualifier="abstract">Modern diagnostic methods form the condition-based maintenance. The way technical systems work requires work without unnecessary downtime and with as few unforeseen errors as possible. When it comes to some of the most common causes related to the operation of rotary machines, the unbalance of the rotor is one of the common problems as well as the misalignment of drive units (electric motors) and the executive element, the impeller. These two mentioned phenomena affect the reliability of operation and the service life of the machine, as they largely lead to damage of bearings, covered shaft, gears if they exist in the system and in order to avoid such issues, it is necessary to spot problems in time, which can be achieved by implementing vibrodiagnostics as a method for condition monitoring of the system. Based on the data obtained through the vibration information, appropriate corrective measures, laser alignment or dynamic rotor balancing are approached.</dim:field>
                    <dim:field mdschema="dc" element="type">bookPart</dim:field>
                    <dim:field mdschema="dc" element="publisher">Springer, Cham</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="spage">164</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="epage">182</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="doi">10.1007/978-3-031-19499-3_9</dim:field>
                    <dim:field mdschema="dc" element="source">In: Mitrovic, N., Mladenovic, G., Mitrovic, A. (eds) Experimental Research and Numerical Simulation in Applied Sciences. CNNTech 2022. Lecture Notes in Networks and Systems, vol 564</dim:field>