<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-05-10T08:01:39.878Z</responseDate>
    <request verb="GetRecord" identifier="ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai:2:8203" metadataPrefix="dim">http://ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai:2:8203</identifier>
                <datestamp>2021-05-07T21:28:59Z</datestamp>
                <setSpec>2</setSpec>
            </header>
            <metadata>
                <dim:dim>
                    <dim:field mdschema="dc" element="title" lang="en">Thermal performances and their impact on design of bayonet-tube heat exchangers – single phase plug flow</dim:field>
                    <dim:field mdschema="dc" element="date" qualifier="issued">2019</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="uri">http://ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai/record/2/8203</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:33725" confidence="-1">М. Ивошевић</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="etfid:980" confidence="-1">A. Petrović</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:33727" confidence="-1">Б. Јаћимовић</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:33728" confidence="-1">С. Генић</dim:field>
                    <dim:field mdschema="dc" element="description" qualifier="abstract">In this paper functional relationships between bayonet-tube heat exchanger effectiveness (P), heat capacity ratio (R) and number of transfer units (NTU) for all possible flow arrangements are derived. Temperature profiles of hot and cold fluid are also given. Analysis showed that regarding heat exchanger surface eight possible flow arrangements can be reduced to four. Furthermore it has been shown which flow arrangements have superior thermal performances. Developed methodology was illustrated through the numerical example.</dim:field>
                    <dim:field mdschema="dc" element="type">article</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="spage">2391</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="epage">2407</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="issn">0947-7411</dim:field>
                    <dim:field mdschema="dc" element="source">HEAT AND MASS TRANSFER</dim:field>