<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-05-09T14:30:26.534Z</responseDate>
    <request verb="GetRecord" identifier="ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai:1:10299" metadataPrefix="dim">http://ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai:1:10299</identifier>
                <datestamp>2024-11-11T08:59:37Z</datestamp>
                <setSpec>1</setSpec>
            </header>
            <metadata>
                <dim:dim>
                    <dim:field mdschema="dc" element="title" lang="en">Monitoring of temperature distribution in ventilation mill in thermal power plant</dim:field>
                    <dim:field mdschema="dc" element="date" qualifier="issued">2015</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="udc">ISSN: 1843-6609</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="uri">http://ezaposleni.singidunum.ac.rs/rest/sciNaucniRezultati/oai/record/1/10299</dim:field>
                    <dim:field mdschema="dc" element="identifier" qualifier="uri">https://drive.google.com/file/d/1Ctb8TlaS4vb5hK4r7PJ93rlx8turlzQQ/view?usp=drive_link</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="orcid::0000-0001-7412-7870" confidence="-1">J. Perišić</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:48122" confidence="-1">LJ. Radovanović</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:48123" confidence="-1">E. Desnica</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:48124" confidence="-1">J. Pekez</dim:field>
                    <dim:field mdschema="dc" element="contributor" qualifier="author" authority="id:48125" confidence="-1">I. Palinkaš</dim:field>
                    <dim:field mdschema="dc" element="description" qualifier="abstract">Within the programme of preventive maintenance it is perform regular thermographic investigations of power plant elements. In this paper we presented application of the thermographic method of ventilation mill of thermal power plant.
The temperature distribution at the outer side of the mill housing ventilation was monitored and temperature measurement at the entrance to the mill. Two contact methods where selected: thermography and measurement of infrared thermometer (IR camera FLIR, TC 335 and IR thermometer BP 20).</dim:field>
                    <dim:field mdschema="dc" element="type">conferenceObject</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="spage">3</dim:field>
                    <dim:field mdschema="dc" element="citation" qualifier="epage">8</dim:field>
                    <dim:field mdschema="dc" element="source">2015 XVIIth Symposium Young people and Multidisciplinary Research, EDITURA POLITEHNICA, Timisoara, Romania</dim:field>
                </dim:dim>
            </metadata>
        </record>
    </GetRecord>
</OAI-PMH>